In Stock. A limit switch is a device that’s located under your furnace’s supply plenum. Compare. The limit switch is a temperature sensor attached to a mounting plate inside the furnace housing. Rather, it is wired in series with the 24-volt control circuit of your furnace. B1388803-AMA3 Furnace Panel Latch ... $14.13 In-Stock. ... Goodman 0130F00038 Auxiliary Limit Switch - Light Blue (0) $5.95 / ea. A pair of wires is connected to the switch. Compare. $42.00. The circuit bd. Pressure switch. This 1370902S limit switch is a guaranteed genuine Goodman OEM replacement for several Goodman, Amana, and Janitrol units. I received a roll out switch I ordered a pressure limit switch. This fan and limit control combines, in one enclosure, a fan switch with an adjustable differential which operates the blower in a forced warm air furnace and a limit switch with a fixed differential which automatically shuts off the burner if the furnace temperature exceeds a predetermined high point. use a multimeter to measure ac voltage drop across the limit switch, will be 0v when closed and 24v approx when open. All Goodman Gas Furnace parts are brand new in the original factory packaging and are guaranteed to fit and function properly. Note that the limit switch has nothing to do with the thermostat. When the furnace … The high limit switch in your gas furnace is a small part with two very important jobs. $4.64. low airflow can have many causes including closed/covered vents, dirty blower assembly, bad blower motor capacitor, dirty evap coil. 1370908S Furnace High Limit Switch. A Goodman furnace with four blinks could be indicating that you are reaching a high limit. The most likely causes of this are plugged or dirty furnace filters, a return air grill that is covered over or too many warm air vents closed off. 4. Amana Goodman Furnace 101235-34 High Limit Switch L220F Manual Reset 10123534. The B13709-08 sometimes has part numbers: B13709-08S, B1370908S or B1370908. I have a Goodman PGB048075-1 furnace. It could also be the pressure switch, or blockage in the vent. It's possible to reset the switch at home when necessary by following a few simple steps. Page of 5 Go. Goodman Amana Furnace Manual Reset Limit Switch 10123522 101235-22 L350F 350. Buy It Now. Good morning all, Im having some trouble with my one year old Goodman GMVC95 variable speed, condensing furnace. ICP 1013102 Flame Rollout Limit Switch. It reads the temperature of the plenum and waits until it gets appropriately warm. What does open high limit mean on a Goodman furnace? 1-year accident protection plan from SquareTrade - $5.99 1-year accident protection plan from SquareTrade - $5.99 Opens an information Overlay. Goodman Furnace Limit Switch. The furnace should fire unless the switch is stuck open. $5.95 / ea. Goodman B1370900 L150 Limit Switch. Related Articles & Videos. 10735003A Amana/Goodman Furnace Ignitor. C $20.69. Ensure the power works through the switch, breaker, fuse and indicator light. If any of the limit switches are open, the furnace will lockout, the circulating fan will come on and a lockout code will be displayed. The B1370910S limit is used on Goodman furnace models: GMPN100-4 and GMPN120-5. It makes this easy to install, and you can normally buy this from one of the local suppliers. Add to Watchlist Unwatch. Brand New. The B13709-08 Goodman Janitrol Limit Control Switch breaks the furnace circuit when the temperature inside the furnace heat exchanger reaches a temperature of 160 degrees. Is B25578-00A. … limit switch tripping is caused by low airflow and/or furnace being oversized. Goodman 1370910S B13709-10 Limit Switch. Once the plenum reaches a specific temperature, the limit switch sends a signal to the air handler to begin running and delivering warm air to your home. The high limit switch is bad. The function of your furnace limit switch is to tell the fan when to turn off and on depending on the temperature in the home. Look at the filter. This is the role it plays in every cycle of your furnace’s normal operation. Goodman gas furnaces have two separate limit circuits. $24.66 In-Stock. The furnace is overheating, which causes the limit switch to shut off the burners. However, for your own safety, don't attempt to reset the switch without first consulting your furnace's instruction manual. C6437502 Amana/Goodman Furnace Flame Sensor. Goodman 20162904 150°/110° Primary Limit Switch 4.5 out of 5 stars 49. If the pressure switch closes, the prepurge will begin. 10123525 Furnace Limit Switch. B. We can help you save money on your Goodman furnace repair, and we can also provide technical advice. The IFC will look at the limit switches. The blower will continue to run until either the system is reset, or the limit switch closes. ICP Heil Tempstar 1065294 L140-30°F Limit Switch . This is a Brand New Goodman/Janitrol 7" Main Limit Switch rated at 160 Degrees (L160-30). The problem is that I get very short (2 minute) burner cycles. $88.00. Purchased new thermostat to rule out the existing one as faulty. $48.36 In-Stock. When the burners go out there are 4 blinking red lights on the control board which indicates 'open high limit' per the troubleshoot references. If the high limit switch was bad, the furnace should not fire. A high-efficiency condensing furnace is a little more complex than a conventional furnace, and troubleshooting is somewhat more complicated since there are more potential problems. ADD TO CART. HVAC systems are designed for safety, so they usually won't turn on at all if there's a faulty part, such as a pressure switch or flame sensor. Watch Video. What Is The Phone Number For Goodman? But remember to consult an HVAC pro for repairs you're not confident about doing yourself. 1 product rating - OEM Goodman Janitrol Furnace 7" Limit Switch 160 L160-30 B13709-08 B1370908. Compare. 10/14 an oil furnace or another application where high temperatures threaten or jeopardize the Nominal Width for Gas Flame Rollout Limit Switch – Part # 2645900 Mfg Part network of goodman parts manual is devoted to GOODMAN GAS FURNACE INSTALLATION MANUAL Goodman ... Payne HVAC high limit switch. Out Of Stock. The new stat produced the same symptoms. All of our parts are shipped factory direct, giving you the assurance you need for a quality repair on your furnace, air conditioner, or other Goodman product. $ 19.95 Quantity: Limit Switch - 1370902S quantity Add to cart Thanks for looking and good l This switch plays a role in the normal operation of your furnace. Manually Resetable Switch. Limit 200°F Possible Repair Solution For: Will not start, no heat, not enough heat, will not shut down on overheat, too much heat, furnace runs too long Please Note: This is intended as a guideline only, as other items can cause the same symptoms. Hello, Ive been having problems with my goodman furnace. B13701-45 - Goodman OEM Furnace Replacement Limit Switch L300. 200 sold. Turning the fan motor on and off is the high limit switch’s main job. B13701-88 - Goodman OEM Furnace Replacement Limit Switch L170-30. The B1370910S Goodman Amana Furnace Limit Switch breaks the furnace circuit when the temperature inside the furnace heat exchanger reaches a temperature of 170 degrees. Goodman Gmt Furnace Open Limit Switch Problem Doityourself Munity Forums. Add To Cart. Sign in to check out Check out as guest . X … $14.13 Special Order. Goodman Furnace Limit Switch. C $32.62. This piece is in control of activating the blower fan to circulate air through the heat exchanger and into the house while also pulling cool air into the unit. Get genuine Goodman factory OEM Gas Furnace for your Goodman unit. If the limit switches are closed, the the warmup time for the HSI begins. If you want to get your furnace repaired, you will likely have to call your HVAC technician. The B13709-08 Goodman Janitrol Limit Control Switch is a brand new Goodman Amana OEM furnace part. Goodman technical support will usually only assist authorized Goodman technicians. $62.00. ADD TO CART. Genuine OEM Part # 20197311 | RC Item # 2645596. My furnace has two roll out switches with a reset button and one that is like the one in the picture. Genuine Carrier HH12ZB180 Furnace High Limit Switch. $26.42. Goodman furnace pressure switch stuck what is a high temperature limit switch goodman furnace limit switch wiring goodman gmes800804bn 80 000 btu furnace goodman hvac control board 4 blinks. Checked for continuity at the high limit switch while it was hot/open (no) and again after it had cooled/closed (yes). Goodman GMT Furnace open limit switch problem. One circuit for the roll out limits (located on the housing surrounding the main burner compartment), and one circuit for the main limit, located above the main burner compartment (it will be about the same height as the top of the main gas valve) and centered in the middle of the gas furnace. The Part number is B13709-08 (also replaces B13709-08S & B13700-08). Sorry in advance for my drawn out description, but here is the background info: This furnace worked fine for the last year, my troubles started this year. Watch Video. I was told the pcb was replaced at the very most 5 years ago along with a new blower motor when furnace was serviced. Or will it work with the limit switch bypassed. In Stock. As an armature, I have some experience troubleshooting furnace problems. Goodman 1370900S Replaces B1370900 3" 150 Degree Limit Switch. Add To Cart. When the high limit switch trips, the flame/heating element will be shut off and the blower will continue to run to clear the heat. This Limit Switch goes on many Goodman/Janitrol furnaces. … Is that because I need to replace the high limit switch in order for the air conditioner to work. The manual reset rollout limit (upper left one) on the back wall of the upper compartment frequently trips open. I have a 2002 5 ton goodman furnace. From United States. CDN$19.99. High-efficiency furnaces are often known as condensing furnaces because they have a second heat exchanger that extracts additional heat from the air that passes through the first heat exchanger. 4.3 out of 5 stars 146. 0130F00486 Goodman Furnace Pressure Switch. The high limit switch shuts down the furnace at a set limit so a clog doesn’t burn out the system. Here are some of the things that you should keep in mind with Goodman furnace troubleshooting issues: Examine the settings on the thermostat. If you want to reset the lockout just turn the power off to the furnace then turn it back on. 4.3 out of 5 stars 22. B. $9.30 OneTrip Parts Furnace Pressure Switch High Temp Tubing 3/16 I.D. I have a 1.5 ton Goodman furnace that cools and heats. B13701-55 - Goodman OEM Furnace Replacement Limit Switch. Mr. Heater High Limit Switch 4.4 out of 5 stars 43. $7.58 In-Stock. My furnace works for several minutes then shuts down and restarts every few minu... Primary/Secondary limit switch open for Lennox G26Q2-50-4. Genuine OEM Part # 20162906 | RC Item # 2645579. I bypassed the limit switch and the heater worked fine, but when I tried to test the air conditioner it wouldn’t work. After the switch opens so many times it will go into soft lockout, which causes the furnace to lockout for 1 hour. Add To Cart. CDN$ 17.01 Mr. Heater High Limit Switch. Top Rated Seller Top Rated Seller. Add to cart . Goodmanmfg.com. Goodman Furnace Pressure Switch. A. Limit Switch.